Thank you for choosing an ARITECH security system. This manual explains how to use the ARITECH CD72 and CD95 series for every day use. There is a. A dual com polls to the monitoring station. What this means is every couple of minutes (depending on what it is set up for) it sends a signal to the monitoring. Hello, I want to integrate a solution based on PLUGWISE and an Aritech Alarm Central. I could successful connect a printer SERIAL RS

Author: Bracage Mauzuru
Country: Ghana
Language: English (Spanish)
Genre: Relationship
Published (Last): 6 June 2017
Pages: 391
PDF File Size: 13.1 Mb
ePub File Size: 12.79 Mb
ISBN: 506-8-51772-862-1
Downloads: 93701
Price: Free* [*Free Regsitration Required]
Uploader: Sacage

No part of this publication may be reproduced, transmitted, stored aritecb a retrieval system, or transmitted in any form, or by any means – electronic, arifech, recording, or otherwise – without the prior written permission of SLC BV. Further SLC BV reserve the right to revise this publication and to make changes from time to time in the contents hereof without the obligation of SLC BV to notify arutech person of any such revision. When used in conjunction with the Programming Manual and the User Manual, it provides the installation engineer with basic installation and programming information.

Everybody involved in installing or maintaining this panel should have access to a copy of this manual. Separate alarm and tamper connection Overview of the dipswitches on remotes Keys on a CD30xx Use of an extra power supply Dual loop connection of a detector without memory Dual loop connection of a detector with latch Connection of a key switch with LED’s Connection of a dc72 detector Connection of a relay or an LED on the output If the following guidelines are followed, the system should give many years of reliable service.

Can I get a GSM dailer in a aritech CD72 panel – Page 2 –

Ensure that there is a good earth for the alarm system. Maintain a good separation between low sritech and mains supply cables, and use separate points of entry into the control panel cabinet.

Avoid loops of wire inside the control panel and route cables so they do not lay on top or underneath the printed circuit board. The use of cable ties is recommended and improves cd722 in the box.

Mains switching relays must NOT be fitted inside the control arihech cabinet. The switching of these relays may cause electrical interference. The greatest care should therefore be taken when installing this cable. NEVER split this cable into separate cables. Avoid cable ducts and cable ways which contain mains power cables.

  BERNA MORAN EDEBIYAT KURAMLAR VE ELETIRISI PDF

Aritech Advisor CD72 Installation Manual

This is particularly important when such ducts contain cables supplying electric motors, fluorescent lights or 3-phase power.

If this is not possible, shielded cable should be used and the cable should be earthed at the control panel end ONLY. Detectors or key switches can be connected in two ways: One zone each is required for both tamper and the alarm.

Both zones should be closed with an end-loop resistor 4. Separate alarm and tamper connection Dual loop: The alarm and tamper are placed together in one zone. The zone has two end-loop resistors 4.

Figure 2 shows how they are connected. The zone is Resistance Panel zone voltages Remote zone voltages Reaction on standby 3k5 – 6k2 2. Set the DIP switches of all the remote keypads and expanders. Remote 1 must be a keypad.

CD, remotes 2 to 4 must be keypads and remotes 5 and 6 expanders. Overview of the dipswitches on remotes 3. Close the tamper switches on the remote keypads, expanders and the control panel.

Aritech TD8803 TD8412

Also close all zones which can cause a direct alarm. If this is not done, the system will be triggered as soon as it is switched on. Supply only mains power to the control panel.

Any zones that may be open will initiate a full alarm condition and the sounders will activate. Do not use a battery to power the system when installing or changing the installation. If there is a short circuit in the 12 volt power supply, the voltage regulators in the supply together with the fuses will prevent serious damage to the system The 12 volt power supply will decrease sharply in the event of a short circuit. If a short circuit should occur, remove the 12 volt connections one by one.

When the connection with the short circuit is removed the power supply will return to 12 volts.

Aritech ADVISOR CD Installation manual |

Every time power is removed from the system the control panel memorises its status. If the sirens have been activated, these will now stop. The status of the system or the time and date will now appear in the display.

Do not forget to initialise additional keypads and expanders with the menu: Take some time to become familiar with the overview of the programming maps which can be found at the end of this manual. Any programming changes made may not take effect until you exit programming mode.

  HORSE MODEL SYNON PDF

The following keys may be used: Keys 9 and 0 have special symbols such as the comma and space.

The arrows move the cursor during entry. To delete a character, overwrite with another character or a space. Keys on a Afitech Note: CD30xx stands for the keypads: Only keypad 1 is operational. The software version is displayed on the other keypads if present. If any zones shown are 24Hr zones e. If dual loop is programmed, the letter T will appear next to the zone number to indicate the tamper section of the loop is open.

Check for open 24Hr zones see above. The dialler may also be programmed via the keypad. A separate manual is available for the dialler. Intended for the manager. Auxiliary power supply PG 4-wire cs72 of keypad or expander Figure Numbering of the inputs Note: In the CD the expanders have priority over the keypads! Dual loop connection of a detector with latch Note: Before connecting, the cable between terminal 2 and terminal 10 should be removed!

Connection of a fire detector Note 1: If there are several detectors place them in parallel and cable the zones as described in figure 1 or 2 see page 8. This connection also applied for detectors which require a reset after an alarm, e. The reset is performed after the second entry of a code after an alarm. Numbering of the outputs NB: In a keypad OA is the buzzer.

This may not be greater than 40 mA. For most LEDs, however, a current of approximately 15 mA is sufficient. The resistance calculation is as follows: Programming for the sirens NB: If the tampers must be placed in separate zones, they can be connected according to figure 1 1 end-loop resistor or figure 2 2 end-loop resistors see page 8.

Cut these 2 aritecj for negative Hold-Off. The other 2 jumpers for positive Hold-Off. Location Output connected max. Overview of the inputs and outputs on the CD Output no. It’s a community-based project which helps to repair anything.